Silicone vulcanizer error solution

The temperature rise process becomes too long or the temperature cannot reach 145. In response to the above problems, check the following steps.

1. The above two kinds of normal but can not increase the temperature, you can check whether the insulation board is moist, if the insulation board

       After seeing water, it is necessary to use the temperature of the hot plate to dry it properly to reach the required temperature.

2. If it is not possible to raise the temperature, check whether the vulcanization time switch in the upper left corner of the control box is on. If it is on, the vulcanizer has entered the holding phase, and the temperature will naturally not rise.

3. After passing the above inspection, if the temperature still cannot be raised, the four-column hydraulic press manufacturer recommends contacting

       The manufacturer conducts further technical consultations or returns to factory maintenance.

4. Whether the heat insulation board is placed between the heating board and the rack, such as no wooden heat insulation board or partition

       If the hot plate is missing, install the heat shield and check the temperature.